E-NANO

Emergency Converter for LED Lighting
DC12V-82V
  • Smart dip 3-pole switches constant current output 100mA-500mA
  • Capable of achieving dimming as norma dimming light.
  • DALl or 0/1 -10V or DMX dimming driver is supportable.
  • Suitable for Maintained or Non-maintained luminaires.
  • Electronic charge system
  • Deep discharge protection
  • Snort-circuit proof battery connection
  • Automatic shutdown protection if the LED load is out of range.
  • Simple wiring /installation.
  • 2 hours or 3hours emergency backup with either Ni-MH battery or Ni-Cd battery
  • Provided with a lP20 robust steel iron remote box
  • Optional IP65 Waterproof Die-casted Aluminum Box Provided with a LED for indication when battery charge is in process.
  • Polarity reversal protection for battery
  •  Tested in accordance with latest local requirement PPA/104(A) (5th Revision).

Technical Data

  • Input Rated Voltage

    Frequency

    • 220-240VAC 50/60Hz
    • 220-240VDC
  • AC Input Current

    50mA

  • AC Input Power Rated

    5W max.

  • Power Factor

    > 0. 9

  • Charge time

    <12 hours

  • No-load Power Consumption

    <1.5W @230VAC

  • Inrush Current

    <36A/420us (230VAC, Full-load)

  • Output emergency power

    Max 30W ----Output Type : Constant Current output

  • Output voltage

    DC10-60V,DC80V Max

  • Smart dip 3-pole switches

    constant current output

    100mA-500mA  (3-pole switch adjustment)

  • Battery Type

    Ni -MH or Ni-Cd battery 

  • Battery Accessories

    • 12V 1.6 AH
    • 12V 2.2 AH
    • 12V 2.5 AH
    • 12V 3.0 AH
    • 12V 4.0AH
    • 12V 5.0AH
    • 12V 6.0AH
    • 9.6V 1.6 AH
    • 9.6V 2.2 AH
    • 9.6V 2.5 AH
    • 9.6V 3.0 AH
    • 9.6V 4.0AH
    • 9.6V 5.0AH
    • 9.6V 6.0AH
  • Luminaires Type

    Maintained   or  Non Maintained Type  refer to wiring diagram 

  • Rated duration

    2 hours  or 3 hours

  • Protection

    • Short Circuit Protection; Overload Protection;No-load Protection;
    • Insulation voltage:I/P to O/P , 3KVac/ 1min; 
    • Insulation resistance >100M ohm @ 500VDC;
    • Leakage current:I/P to O/P < 250 μA
  • Environment

    Ta/Operation Temperature: 0….+50°C

    Ts/Storage Temperature: -25… .+85°C

    Tc/Enclosure Temperature: 70°C max.

    Humidity: 10%....90%RH

  • Construction

    Connection Method: Direct Lead

    PRI Wire preparation: 0.5-1.0 sq.mm

  • Dimension

    210X40X27mm (L*W*H)

  • MTBF

    Switching Testing 

    >100000 hours

    > 10,000 times

  • Life Time

    50,000h @50°C(Ta)/ @70°C(Tc)

  • Plug Terminal

    JST VHR-2N/3.96mm Plug Terminal for Battery and LED indicator Connection

  • Accessories

    • Test switch
    • Status indication LED Light  :GREEN-FULLYCHARGED   ;  RED- CHARGING   ; YELLOW.FAULT
  • Safety Standards

    CE  IEC/EN 61347-1; IEC/EN 61347-2-13; IEC/EN 62384; IEC/EN 61000-3-2; IEC/EN 61000-3-3;IEC/EN61574;EN 55015

  • Housing materials

    Zinc Iron 

  • Housing Color

    White coating

  • Certification

Product Download Tab